副产甲醇作为外加碳源时脱氮效果的应用研究
张乐乐,刘兵,杨号,赵晓峰,耿佳伟
(江苏方洋水务有限公司,江苏 连云港 222065)
摘要:本文以某化工厂副产甲醇(纯度约90%)为碳源,研究了进水PH对脱氮效果的
影响,探索了出水总氮达15mg/L时,对进水总氮的要求。小试结果表明:进水总氮约
15mg/L,PH在7~8.5时,总氮去除率达50%以上,但进水总氮达约29mg/L时,出水总氮有超标的风险。
关键词:副产甲醇,外加碳源,脱氮
Study on the application of nitrogen removal effect of accompanying methanol production as carbon source
Abstract: in this paper, the effect of pH on denitrification was studied by using methanol produced by a chemical plant as a carbon source, and the requirement of 15 mg/L of total nitrogen was explored. The results of the small test showed that the water intake PH was 7 to 8.5, at that time, the total nitrogen removal rate reached more than 50 %, but when the total nitrogen intake reached about 29 mg/L, the total nitrogen outflow had a risk of exceeding the standard.
Key words: secondary production of methanol, plus carbon source, denitrification
Zhang Lele, Liu Bing, Yang Hao, Zhao Xiaofeng, Geng Jiawei
(Jiangsu Fangyang Water Co.,Ltd, Lianyungang 22065,China)
作为细菌代谢的必需物质和能量来源,碳源在污水生物脱氮处理中起着重要的作用,是反硝化反应得以顺利进行的必备条件[1~2]。然外碳源的使用势必会增加污水处理厂的运行费用, 目前对碳源的种类、运行效果及投加量等也有大量的文献报道[3~8]。
盛虹石化产业项目副产甲醇不仅价格低、易获取,且纯度高(纯度约90%),更为有利的是无需在污水厂厂区构建甲醇储存装置,直接用管廊架将甲醇从甲醇储罐泵入厂区投加点,可大大降低运行成本。本文以其作为外加碳源,通过小试研究了进水PH对脱氮效果的影响,探索了出水总氮达15mg/L时,对进水总氮的要求。
1.材料和方法
1.1实验水样
江苏省某新区污水处理厂主要处理新区内的PTA工业污水,一期工程处理规模5万吨/日,远期处理规模为20万吨/日,采用的工艺流程如图1所示。实验所用废水为此工艺的调节罐出水,COD约80mg/L,进水总氮约13~15mg/L,PH8.5~8.8。
图1:工艺流程图
1.2仪器和材料
实验仪器:小试实验装置,含调节罐、A池、O池、二沉池;
实验材料:污泥取自大系统对应工段;盐酸AR(31%),调进水PH;硝酸AR,补充总氮;副
产甲醇(其中甲醇90.75%,硼酸甲酯6.24%,丁酸0.5%,乙酸丁酯1.71%,其它0.8%)
1.3实验方法
根据小试调节罐容量,计算进水负荷所需外加碳源的总量[9,10],准确称量后,一次性加入调节罐并混匀后进样,连续进水,A池搅拌器搅拌,O池采用微孔曝气头曝气,内回流100%,外回流100%,每24h取样检测,测试氨氮、硝态氮及总氮去除效果,持续7天变换一个条件。试验在温度为26 ℃、MLSS为 3033mg/L、MLVSS 为 2023mg/L,A池DO<0.5mg/L,O池DO<5mg/L。
1.4测试方法
NO3-N、NH3-N、总氮采用《水和废水检测分析方法》测定。DO便携式溶氧仪测定,pH便携式pH计测定。
1.5出水执行标准
GB18918-2002《城镇污水处理厂污染物排放标准》一级A标准,出水总氮≤15mg/L
2.结果与讨论
2.1 PH对脱氮效果的影响
用盐酸将调节罐进水PH调为7.45、7.01,考察pH对脱氮效果的影响,如表1所示。由表1可见:进水PH降低至7.45时,总氮去除率略有提高,但是当进水PH继续降低至7.01时,总氮去除率约50%,结合反硝化原理[11]将进水PH调整在7~8.5是比较理想的。
表1:Ph对脱氮效果的影响
指标 |
总氮mg/L |
出水氨氮/硝态氮mg/L |
|||
PH |
进水 总氮 |
出水 总氮 |
去除率 % |
出水硝 态氮 |
出水氨氮 |
8.72 |
14 |
7 |
50 |
3.84 |
1.76 |
7.45 |
15 |
6.84 |
54.4 |
3.86 |
2.88 |
7.45 |
14.7 |
6.92 |
52.9 |
4.13 |
2.44 |
7.45 |
14.7 |
7.05 |
52 |
5.08 |
1.36 |
7.01 |
13.8 |
6.82 |
50.6 |
4.44 |
1.86 |
7.01 |
13.8 |
7.3 |
47.1 |
5.31 |
0.28 |
7.01 |
13.8 |
7.07 |
48.8 |
5.19 |
0.264 |
2.2进水总氮为 20mg/L时,活性污泥对总氮的去除效果
以90%虹港副产甲醇为碳源,加入硝酸将进水总氮调整到约20mg/L,BOD5/TN=4时,活性污泥对总氮的去除效果如表2所示。由表2可见,当进水总氮约为20.36mg/L时,出水总氮约11.6mg/L,总氮去除率43.02%;这可能是由于进水总氮的突然增加,污泥需要一定的适应期。
表2:副产甲醇对总氮的去除效果
出水氨氮/硝态氮mg/L |
||||
进水 总氮 |
出水 总氮 |
去除率 % |
出水硝 态氮 |
出水氨氮 |
19.5 |
11.9 |
38.97 |
7.79 |
2.98 |
18.9 |
11.7 |
38.1 |
9.43 |
0.37 |
21.2 |
11.3 |
46.96 |
10.6 |
0.351 |
21.2 |
11.5 |
45.75 |
8.83 |
2.08 |
21.2 |
13.7 |
35.37 |
9.12 |
2.13 |
21.2 |
11.3 |
46.96 |
10.6 |
0.351 |
21.3 |
11.3 |
46.95 |
2.85 |
4.0 |
19.8 |
11.3 |
42.92 |
6.32 |
4.44 |
19.8 |
10.3 |
47.97 |
4.94 |
3.89 |
2.3进水总氮为25mg/L时,活性污泥对总氮的去除效果
以90%虹港副产甲醇为碳源,BOD5/TN=4时,进水总氮约25mg/L时对总氮的去除效果如表3所示。由表3可见:当进水总氮约为25.38mg/L时,出水总氮约12.43mg/L,总氮去除率51.02%;
表3:副产甲醇对总氮的去除效果
总氮mg/L |
出水氨氮/硝态氮mg/L |
|||
进水 总氮 |
出水 总氮 |
去除率 % |
出水硝 态氮 |
出水 氨氮 |
25.2 |
12.9 |
48.81 |
9.25 |
0.38 |
25.2 |
12.2 |
51.58 |
9.82 |
2.35 |
27.7 |
13.3 |
51.98 |
10.55 |
2.73 |
27.7 |
14.3 |
48.37 |
12.59 |
1.71 |
26.6 |
13.9 |
47.74 |
11.6 |
2.29 |
26.6 |
12.99 |
51.16 |
10.1 |
2.89 |
24.1 |
10.3 |
57.26 |
8.76 |
1.54 |
24.1 |
10.8 |
55.19 |
9.06 |
0.37 |
23.3 |
11.2 |
51.93 |
10.9 |
0.3 |
23.3 |
12.4 |
46.78 |
12.1 |
0.3 |
(3)进水总氮为30mg/L时,活性污泥对总氮的去除效果
以90%虹港副产甲醇为碳源,探索BOD5/TN=4时,进水总氮约30mg/L时,对总氮的去除效果如表4所示。由表4可见:当进水总氮为29mg/L时,出水总氮有超标风险。
表4:副产甲醇对总氮的去除效果
总氮mg/L |
出水氨氮/硝态氮mg/L |
|||
进水 总氮 |
出水 总氮 |
去除率 % |
出水硝 态氮 |
出水氨氮 |
31.2 |
|