副产甲醇作为外加碳源时脱氮效果的应用研究

副产甲醇作为外加碳源时脱氮效果的应用研究

张乐乐,刘兵,杨号,赵晓峰,耿佳伟 

(江苏方洋水务有限公司,江苏 连云港 222065

   摘要:本文以某化工厂副产甲醇(纯度约90%)为碳源,研究了进水PH对脱氮效果的

影响,探索了出水总氮达15mg/L时,对进水总氮的要求。小试结果表明:进水总氮约

15mg/L,PH在7~8.5时,总氮去除率达50%以上,但进水总氮达约29mg/L时,出水总氮有超标的风险。

关键词:副产甲醇,外加碳源,脱氮

Study on the application of nitrogen removal effect of accompanying methanol production as carbon source

Abstract: in this paper, the effect of pH on denitrification was studied by using methanol produced by a chemical plant as a carbon source, and the requirement of 15 mg/L of total nitrogen was explored. The results of the small test showed that the water intake PH was 7 to 8.5, at that time, the total nitrogen removal rate reached more than 50 %, but when the total nitrogen intake reached about 29 mg/L, the total nitrogen outflow had a risk of exceeding the standard.

Key words: secondary production of methanol, plus carbon source, denitrification

Zhang Lele, Liu Bing, Yang Hao, Zhao Xiaofeng, Geng Jiawei

(Jiangsu Fangyang Water Co.,Ltd, Lianyungang 22065,China)

作为细菌代谢的必需物质和能量来源,碳源在污水生物脱氮处理中起着重要的作用,是反硝化反应得以顺利进行的必备条件[1~2]。然外碳源的使用势必会增加污水处理厂的运行费用, 目前对碳源的种类、运行效果及投加量等也有大量的文献报道[38]

盛虹石化产业项目副产甲醇不仅价格低、易获取,且纯度高(纯度约90%,更为有利的是无需在污水厂厂区构建甲醇储存装置,直接用管廊架将甲醇从甲醇储罐泵入厂区投加点,可大大降低运行成本。本文以其作为外加碳源,通过小试研究了进水PH对脱氮效果的影响,探索了出水总氮达15mg/L时,对进水总氮的要求。 

1.材料和方法

1.1实验水样

江苏省某新区污水处理厂主要处理新区内的PTA工业污水,一期工程处理规模5万吨/日,远期处理规模为20万吨/日,采用的工艺流程如图1所示。实验所用废水为此工艺的调节罐出水,COD约80mg/L,进水总氮约1315mg/L,PH8.58.8。

 

 

 

 

 

1:工艺流程图

1.2仪器和材料

实验仪器:小试实验装置,含调节罐、A池、O池、二沉池;

实验材料:污泥取自大系统对应工段;盐酸AR31%,调进水PH;硝酸AR,补充总氮;副

产甲醇(其中甲醇90.75%,硼酸甲酯6.24%,丁酸0.5%,乙酸丁酯1.71%,其它0.8%)

1.3实验方法

根据小试调节罐容量,计算进水负荷所需外加碳源的总量[9,10],准确称量后,一次性加入调节罐并混匀后进样,连续进水,A池搅拌器搅拌,O池采用微孔曝气头曝气,内回流100%,外回流100%,每24h取样检测,测试氨氮、硝态氮及总氮去除效果,持续7天变换一个条件。试验在温度为26 ℃、MLSS为 3033mg/L、MLVSS 为 2023mg/L,A池DO<0.5mg/L,O池DO<5mg/L。

1.4测试方法

NO3-N、NH3-N、总氮采用《水和废水检测分析方法》测定。DO便携式溶氧仪测定,pH便携式pH计测定。

1.5出水执行标准

GB18918-2002《城镇污水处理厂污染物排放标准》一级A标准,出水总氮≤15mg/L

2.结果与讨论

2.1 PH对脱氮效果的影响

用盐酸将调节罐进水PH调为7.45、7.01,考察pH对脱氮效果的影响,如表1所示。由表1可见:进水PH降低至7.45时,总氮去除率略有提高,但是当进水PH继续降低至7.01时,总氮去除率约50%,结合反硝化原理[11]将进水PH调整在7~8.5是比较理想的。

 

1:Ph对脱氮效果的影响

指标

总氮mg/L

出水氨氮/硝态氮mg/L

PH

进水

总氮

出水

总氮

去除

%

出水硝

态氮

出水氨氮

8.72

14

7

50

3.84

1.76

7.45

15

6.84

54.4

3.86

2.88

7.45

14.7

6.92

52.9

4.13

2.44

7.45

14.7

7.05

52

5.08

1.36

7.01

13.8

6.82

50.6

4.44

1.86

7.01

13.8

7.3

47.1

5.31

0.28

7.01

13.8

7.07

48.8

5.19

0.264

2.2进水总氮为 20mg/L时,活性污泥对总氮的去除效果

90%虹港副产甲醇为碳源,加入硝酸将进水总氮调整到约20mg/LBOD5/TN=4时,活性污泥对总氮的去除效果如表2所示。由表2可见,当进水总氮约为20.36mg/L时,出水总氮约11.6mg/L,总氮去除率43.02%;这可能是由于进水总氮的突然增加,污泥需要一定的适应期。

2:副产甲醇对总氮的去除效果

总氮mg/L

出水氨氮/硝态氮mg/L

进水

总氮

出水

总氮

去除

%

出水硝

态氮

出水氨氮

19.5

11.9

38.97

7.79

2.98

18.9

11.7

38.1

9.43

0.37

21.2

11.3

46.96

10.6

0.351

21.2

11.5

45.75

8.83

2.08

21.2

13.7

35.37

9.12

2.13

21.2

11.3

46.96

10.6

0.351

21.3

11.3

46.95

2.85

4.0

19.8

11.3

42.92

6.32

4.44

19.8

10.3

47.97

4.94

3.89

2.3进水总氮为25mg/L时,活性污泥对总氮的去除效果

90%虹港副产甲醇为碳源,BOD5/TN=4时,进水总氮约25mg/L时对总氮的去除效果如表3所示。由表3可见:当进水总氮约为25.38mg/L时,出水总氮约12.43mg/L,总氮去除率51.02%;

表3:副产甲醇对总氮的去除效果

总氮mg/L

出水氨氮/硝态氮mg/L

进水

总氮

出水

总氮

去除

%

出水硝

态氮

出水

氨氮

25.2

12.9

48.81

9.25

0.38

25.2

12.2

51.58

9.82

2.35

27.7

13.3

51.98

10.55

2.73

27.7

14.3

48.37

12.59

1.71

26.6

13.9

47.74

11.6

2.29

26.6

12.99

51.16

10.1

2.89

24.1

10.3

57.26

8.76

1.54

24.1

10.8

55.19

9.06

0.37

23.3

11.2

51.93

10.9

0.3

23.3

12.4

46.78

12.1

0.3

(3)进水总氮为30mg/L时,活性污泥对总氮的去除效果

90%虹港副产甲醇为碳源,探索BOD5/TN=4时,进水总氮约30mg/L时,对总氮的去除效果如表4所示。由表4可见:当进水总氮为29mg/L时,出水总氮有超标风险。

表4:副产甲醇对总氮的去除效果

总氮mg/L

出水氨氮/硝态氮mg/L

进水

总氮

出水

总氮

去除

%

出水硝

态氮

出水氨氮

31.2